Submersible Pumps For Drainage and Waste Water (Domestic Use)
Applications
The submersible pump from the NOVA series is designed mainly for automatically operated fixed
applications in domestic use, draining basements and garages which are subject to flooding.
Thanks to its compact, easy to handle form, it may also be used as a portable pump for emergencies such
as lifting water from tanks or rivers, emptying swimming pools, fountains, excavations and underpasses. It
is also ideal for gardening and hobbies in general.
The submersible pump from the FEKA series has been designed for lifting sewage from cesspools and is
capable of draining suspended solids with dimensions up to 25 mm.
The level switch allows fixed installation and guarantees automatic pump operation.
Constructional features of the pump
Water-resistant technopolymer pump body, impeller, top body and suction grid.
Stainless steel motor, rotor shaft and screws.
Triple O-ring seals interposed with oil chamber.
Constructional features of the motor
Continuous duty submersible induction motor. Stator fitted in an airtight stainless steel casing covered by a
top body which contains the cabling, microswitch and capacitor. Rotor mounted on oversized greased
sealed-for-life ball bearings to ensure silent running and long life. Built-in thermal and current overload
protection and a capacitor permanently in circuit in the single-phase version. Three-phase motors should
be protected with a suitable overload protection complying with the regulations in force.
Manufactured according to CEI 2-3 and CEI 61-69 standards (EN 60335-2-41).
- Motor protection: IP68
- Insulation class: F
- Standard voltage:
- single-phase 220-240 V/50 Hz
- three-phase 400 V/50 Hz
- Standard cables for the single-phase version:
- 5 metres H05 RN-F NOVA 180 M-A - NOVA 300 M-A
NOVA 600 M-A - FEKA 600 M-A
- 10 metres H05 RN-F NOVA 180 M-NA - NOVA 200 M-NA
- 10 metres H07 RN-F NOVA 600 M-NA - FEKA 600 M-NA
- Standard plug for the single-phase version: SCHUKO CEE 7 - VII - UNEL 47166-68
- Standard cables for the three-phase version: 5 metres H07 RN-F
Technical Data:
- Operating range: from 1 to 16 m3/h with head up to 10.2 metres
- Liquid quality requirements:
- NOVA cloudy water without fibres
- FEKA sewage from cesspools
- Free passage of solids through the suction grid:
- NOVA 180 - NOVA 200 5 mm
- NOVA 300 - NOVA 600 10 mm
- FEKA 600 25 mm
- Minimum draught depth:
- NOVA 180 77 mm
- NOVA 200 - NOVA 180 NA 8 mm
- NOVA 300 85 mm
- NOVA 600 A - FEKA 600 A 175 mm
- NOVA 600 NA - FEKA 600 NA 48 mm
- Liquid temperature range: from 0°C to +35°C for domestic use (EN 60335-2-41)
- Maximum immersion depth: 7 metres
- Maximum dry running time: 1 minute
- Installation: fixed or portable in a vertical position
Click here for - Submersible Pump Selection Table

Dimensions and Weights
Type |
A |
B |
C |
D |
E |
H |
H1 |
H2 |
LIV. MIN |
LIV. MAX |
DNM |
Packing Dimensions |
Volume m³ |
Weight Kg |
| L/A |
L/B |
H |
NOVA 300 M-A |
181 |
235 |
46 |
296 |
82 |
262 |
354 |
47 |
85 |
285 |
1¼"G |
287 |
202 |
320 |
0.019 |
4.6 |
| Available Options: |
| Stainless Steel Axle: |
|
|