CIRCULATORS FOR HOT WATER SYSTEM
Pump for hot water circulation in hot water domestic systems of the closed and
pressurised or open tank type. Also suitable for solar power systems.
Single body formed of the bronze hydraulic unit. Die-cast aluminium motor
casing. Technopolymer impeller. Ceramic driving shaft mounted on graphite
brushings lubricated by the pumped liquid itself.
Stainless steel protective rotor sleeve, stator sleeve and closing flange.
Ceramic thrust bearing, E.P.D.M. “O” rings.
The two-pole or four-pole asynchronous motor with wet rotor is self-protected for
resistance. No overload protection required.
- Operating range: from 0.6 to 4,2 m3/h with head up to 6.3 metres.
- Liquid temperature range:
- from -10°C to +85°C (for sanitary use)
- +110°C (for others use).
- Pumped liquid characteristics:clean, free from solids and mineral oils, non viscous,
chemically neutral, close to the characteristics of water (max 30% glycol).
- Maximum working pressure: 10 bar (1000 kPa ).
- Protection level: IP 44
- Insulation class: F
- Cable grommet: PG 11
- Installation: with motor axis horizontal.

DIMENSIONS AND WEIGHTS
Pump |
L |
L1 |
L2 |
B |
B1 |
B2 |
H |
H1 |
H2 |
F |
PACKING DIMENSIONS
|
VOLUME m³ |
WEIGHT Kg |
| L |
B |
H |
|
150 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
1½"G |
130 |
185 |
135 |
0.0032 |
2.6 |
|
150 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
1½"G |
130 |
185 |
135 |
0.0032 |
2.6 |
|
150 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
1½"G |
130 |
185 |
135 |
0.0032 |
2.6 |
|
150 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
1½"G |
130 |
185 |
135 |
0.0032 |
2.6 |
| Pump |
VOLTAGE 50 Hz |
CENTRE DISTANCE |
UNIONS ON REQUEST |
ELECTRICAL DATA |
MINIMUM HEAD PRESSURE |
| n. r.p.m. |
P1 MAX W |
In A |
µF |
Vc |
|
1x230 V ~ |
130 |
BRASS: 1/2” F - 3/4” F - 1” F
COPPER: Ø 22 - Ø 28 |
1225 |
40 |
0.23 |
2 |
450 |
t° +60°C mt. 1.5 |
|
1x230 V ~ |
150 |
2680 |
54 |
0.25 |
1.5 |
450 |
t° +60°C mt. 1.5 |
|
1x230 V ~ |
150 |
2360 |
71 |
0.32 |
2 |
450 |
t° +60°C mt. 1.5 |
|
1x230 V ~ |
150 |
2105 |
105 |
0.45 |
2.5 |
450 |
t° +60°C mt. 1.5 |