CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS
Single body consisting of a cast iron hydraulic unit. Die-cast aluminium motor
casing.
Technopolymer impeller. Tempered stainless steel driving shaft mounted on
graphite brushings lubricated by the pumped liquid itself.
Stainless steel protective rotor sleeve, stator sleeve and closing flange.
Ceramic thrust bearing, E.P.D.M. O-rings and brass air outlet cap.
The two-pole asynchronous motor with wet rotor is self-protected for resistance.
No overload protection required. Three-speed operation.
In the twin version an automatic clapet type valve is provided.
- Operating range: from 0.5 to 4 m3/h with head up to 6.3 metres.
- Liquid temperature range: from -10°C to +110°C.
- Pumped liquid characteristics: clean, free from solids and mineral oils, non
viscous, chemically neutral, close to the characteristics of water (max 30% glycol).
- Maximum working pressure: 10 bar (1000 kPa).
- Protection level: corresponding to IP 44
- Insulation class: F
- Cable grommet: PG 11
- Installation: with motor axis horizontal.

DIMENSIONS AND WEIGHTS
Pump |
L |
L1 |
L2 |
B |
B1 |
B2 |
H |
H1 |
H2 |
F |
PACKING DIMENSIONS |
VOLUME m³ |
WEIGHT Kg |
| L |
B |
H |
|
130 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
1½" G |
138 |
140 |
135 |
0.0026 |
2.65 |
|
180 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
1½" G |
138 |
140 |
135 |
0.0036 |
2.8 |
|
180 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
2" G |
138 |
190 |
140 |
0.0036 |
2.8 |
|
130 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
1½" G |
138 |
140 |
135 |
0.0026 |
2.65 |
|
130 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
1"G |
138 |
140 |
135 |
0.0026 |
2.65 |
|
180 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
1½" G |
138 |
190 |
140 |
0.0036 |
2.8 |
|
180 |
98 |
60 |
104 |
78 |
26 |
124 |
75 |
49 |
2" G |
138 |
190 |
140 |
0.0036 |
2.8 |
| Pump |
VOLTAGE 50 Hz |
CENTRE DISTANCE |
UNIONS ON REQUEST |
ELECTRICAL DATA |
MINIMUM HEAD PRESSURE |
| STANDARD |
SPECIAL |
SPEED |
n. r.p.m. |
P1 MAX W |
In A |
µF |
Vc |
|
1x230 V ~ |
130 |
1" F |
¾"F - 1¼"M |
3 |
2590 |
57 |
0.26 |
1.5 |
450 |
t° +90°C mt. 1.5 |
2 |
2320 |
50 |
0.24 |
1 |
1895 |
38 |
0.18 |
|
1x230 V ~ |
180 |
1" F |
¾"F - 1¼"M |
3 |
2590 |
57 |
0.26 |
1.5 |
450 |
t° +90°C mt. 1.5 |
2 |
2320 |
50 |
0.24 |
1 |
1895 |
38 |
0.18 |
|
1x230 V ~ |
180 |
1"¼ F |
3 |
2590 |
57 |
0.26 |
1.5 |
450 |
t° +90°C mt. 1.5 |
2 |
2320 |
50 |
0.24 |
1 |
1895 |
38 |
0.18 |
|
1x230 V ~ |
130 |
1" F |
¾"F - 1¼"M |
3 |
2370 |
71 |
0.31 |
2 |
450 |
t° +90°C mt. 1.5 |
2 |
1910 |
60 |
0.28 |
1 |
1440 |
44 |
0.2 |
|
1x230 V ~ |
130 |
- |
- |
3 |
2370 |
71 |
0.31 |
2 |
450 |
t° +90°C mt. 1.5 |
2 |
1910 |
60 |
0.28 |
1 |
1440 |
44 |
0.2 |
|
1x230 V ~ |
180 |
1" F |
¾"F - 1¼"M |
3 |
2370 |
71 |
0.31 |
2 |
450 |
t° +90°C mt. 1.5 |
2 |
1910 |
60 |
0.28 |
1 |
1440 |
44 |
0.2 |
|
1x230 V ~ |
180 |
1"¼ F
|
3 |
2370 |
71 |
0.31 |
2 |
450 |
t° +90°C mt. 1.5 |
2 |
1910 |
60 |
0.28 |
1 |
1440 |
44 |
0.2 |
Click Here For - Circulation Pump Selection Table
Click here for Pumps and Additions Selection Table
|